Accéder directement au contenu Accéder directement à la navigation
Article dans une revue

Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis:

Abstract :

Background/aims: As a module of a standard ultrasound imaging device, acoustic radiation force impulse (ARFI) is a new technology for liver stiffness evaluation (LSE). We aimed to evaluate accuracy, feasibility, reproducibility, and training effect of ARFI for liver fibrosis evaluation.Methods: One hundred and one patients with chronic liver disease had LSE by Fibroscan and ARFI. LSE by ARFI was performed in the two liver lobes by two operators: an expert and a novice. Correlation and agreement were evaluated by the Pearson (Rp) and intraclass (Ric) correlation coefficients. The independent reference for liver fibrosis was fibrosis blood tests. Results: ARFI results, ranging from 0.7 to 4.6 m/s, were well correlated with Fibroscan results (Rp=0.76). Fibroscan had a significantly higher area under the receiver operating characteristic curve (AUROC) than ARFI for the perprotocol diagnosis of significant fibrosis: 0.890±0.034 versus 0.795±0.047 (P=0.04). However, LSE failure occurred in zero patients using ARFI versus six patients using Fibroscan (P=0.03). Thus, on an intention-to-diagnose basis, Fibroscan and ARFI AUROCs for the diagnosis of significant fibrosis were not different: 0.791±0.049 versus 0.793±0.046 (P=0.98). Interobserver agreement was very good (Ric=0.84) and excellent for ARFI interquartile range (IQR)≤0.30 (Ric=0.91). Indeed, agreement was independently predicted only by ARFI IQR, but not by LSE result as earlier observed for Fibroscan. ARFI AUROC was 0.876±0.057 in patients with ARFI IQR ratio≤0.30, and Fibroscan AUROC was 0.912±0.034 in patients with Fibroscan IQR ratio less than 0.21 (P=0.59). Intersite ARFI agreement between the two liver lobes was fair (Ric=0.60). There was no training effect for LSE by ARFI. Conclusion: ARFI is highly feasible and reproducible, and provides diagnostic accuracy similar to Fibroscan. This new device seems noteworthy for the widespread noninvasive diagnosis of liver fibrosis.

Type de document :
Article dans une revue
Liste complète des métadonnées

https://hal.univ-angers.fr/hal-03267608
Contributeur : Okina Université d'Angers <>
Soumis le : mardi 22 juin 2021 - 15:21:51
Dernière modification le : mercredi 23 juin 2021 - 03:34:48

Identifiants

Collections

Citation

Jérôme Boursier, Gael Isselin, Isabelle Fouchard-Hubert, Frédéric Oberti, Nina Dib, et al.. Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis:. European Journal of Gastroenterology and Hepatology, Lippincott, Williams & Wilkins, 2010, 22 (9), pp.1074 - 1084. ⟨10.1097/MEG.0b013e328339e0a1⟩. ⟨hal-03267608⟩

Partager

Métriques

Consultations de la notice

13