In vivo osseointegration and erosion of nacre screws in an animal model - Université d'Angers Accéder directement au contenu
Article Dans Une Revue Journal of Biomedical Materials Research Part B: Applied Biomaterials Année : 2020

In vivo osseointegration and erosion of nacre screws in an animal model

Résumé

The use of resorbable devices for osteosynthesis has become a subject of interest. Nacre has been proposed as a resorbable and osteoconductive material favoring bone apposition without triggering an inflammatory reaction. We compared the in vivo osseointegration and erosion of nacre screws in an animal model with titanium screws. Implantation of similar nacre and titanium screws was performed in the femoral condyles of adult rats. Animals (n = 41) were randomized in four groups sacrificed at day one, 1, 6, and 12 months. Microcomputed tomography (microCT) allowed 3D morphometry of erosion of nacre. Osseointegration was measured as the volume of trabecular bone bone volume/tissue volume (BV/TV) in a standardized volume of interest around each screw. Undecalcified bone histol-ogy was also done. Gross examination revealed a similar clinical osseointegration for titanium and nacre screws. A progressive erosion of nacre screws, but no erosion of titanium screws, was observed in microCT. The volume of nacre screws progressively decreased over time whereas no modification occurred for titanium. For titanium screws, BV/TV remained stable throughout the study. For nacre screws, the BV/TV decrease was not statistically different. A significant difference was found between nacre and titanium screws at 6 months but not at 12 months. The screw heads, outside the bone shaft, were not eroded even after 12 months. Erosion of nacre occurred during the entire study period, only within the bone shaft in direct contact with bone marrow. Bone apposition was observed on nacre surfaces without signs of erosion. Nacre is a promising biomaterial in maxillofacial surgery. K E Y W O R D S erosion, maxillofacial surgery, mother of pearl, nacre, osseointegration, resorbable device, titanium screw
Fichier principal
Vignette du fichier
HAL ARTICLE vis en nacre rat 2020.pdf (1.52 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02975091 , version 1 (22-10-2020)

Identifiants

Citer

Jean-Daniel Kün-Darbois, Hélène Libouban, Georges Camprasse, Serge Camprasse, Daniel Chappard. In vivo osseointegration and erosion of nacre screws in an animal model. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2020, ⟨10.1002/jbm.b.34743⟩. ⟨hal-02975091⟩

Collections

UNIV-ANGERS
83 Consultations
171 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More